Revised: 7/22 Winston Company, Inc. CrystalClear®
Polish Activated Carbon
SECTION 1 – IDENTIFICATION
Trade Name: CrystalClear® Polish Activated Carbon
Name and/or Family or Description: Coal-Based Activated
Carbon Chemical Formula: N/A CAS No.: N/A DOT
Proper Shipping Name: Chemicals Not Otherwise Indexed (NOI)
Non-Hazardous DOT Hazard Class: Not Regulated DOT
Label: None
SECTION 2 - COMPONENTS (Hazardous &
Other)
Hazardous Ingredients: None Known
Other
Ingredients CAS No. Activated Carbon [7440-44-0]
SECTION 3 - PHYSICAL DATA
State: Pellet
Appearance: Black Odor: Slight Coal Odor Boiling
Point: N/A Melting Point: N/A Vapor Pressure: (mmHg at
20C): Zero Vapor Density: (Air=1): N/A Solubility In
Water: Insoluble In Water & Oraganic Solvents Storage
Conditions: Store Tightly In Cool, Dry Place pH: N/A
Specific Gravity: 350-600 g/l % Volatile By Volume: Less
Than 1.0% At 150C SECTION 4 - FIRE AND EXPLOSION HAZARD
DATA
Flash Point: Not Flammable
Ignition
Temperature: Powdered – No Generally Accepted Test
Granular – About 450C (ANSI/ASTM D3466) Pellet – About
450C (ANSI/ASTM D3466)
*All carbonaceous materials
will burn under certain conditions and activated carbons are
no exception. Activated carbons, however, are not highly
flammable and burn slowly without producing smoke or flame.
Extinguishing Media: Water (Fog or Fine Spray), Carbon
Dioxide Avoid Methods Which May Stir Up Dust Clouds
Special Fire Fighting Protective Equip.: Self-Contained
Breathing Apparatus Unusual Fire Explosion Hazards:
Airborne Dust Is A Weak Explosion Hazard
SECTION 5 -
REACTIVITY DATA
Stability: Stable Under Normal
Conditions Incompatibility (Materials To Avoid): Strong
Oxidizing Agents, Fluorine Hazardous Decomposition
Products: Carbon Dioxide, Carbon Monoxide Hazardous
Polymerization: Will Not Occur
SECTION 6 - HEALTH
HAZARD DATA
General: No toxicity data is available.
Physical and chemical properties of activated carbon are
used for the health hazard assessment. Carcinogenicity:
Activated carbon is not listed in the National Toxicology
Program (NTP) Annual report on carcinogens nor has it been
found to be a potential carcinogen in the International
Agency for Research on Cancer (IARC) monographs or by OSHA.
Ingestion: The acute oral LD50 values are not available.
Relative to other materials, a single dose of this product
is relatively harmless by ingestion. Hodge, H.C. and
Sterner, J.H., American Industrial Hygiene Association
Quarterly, 10:4, 93, Dec. 1949
Eye Contact: This
material will probably cause some mild physical irritation
if contact is made with human eyes.
Skin Contact:
This material is not likely to be a primary irritant on
human skin; it has a low potential for sensitization after
skin contact.
Skin Absorption: This product is not
known to be absorbed through the skin.
Inhalation:
Acute toxic effects are not likely to develop after
inhalation from this material.
Effect of
Overexposure: No adverse clinical effects have been
associated with exposures to this material.
Skin:
Wash material off the skin with water and soap. If redness,
itching or a burning sensation develops, get medical
attention.
Eyes: Immediately flush with copious
amounts of water. If redness, itching or a burning sensation
develops, have eyes examined and treated by medical
personnel.
Ingestion: Give one or two glasses of
water to drink. If gastrointestinal symptoms develop,
consult medical personnel. (Never give anything by mouth to
an unconscious person.)
Inhalation: Remove victim to
fresh air. If cough or other respiratory symptoms develop,
consult medical personnel.
SECTION 7 - SPILL, LEAK,
AND DISPOSAL INFORMATION
Steps to be taken in case
material is released or spilled: Wear respiratory protection
during clean-up. Sweep up and recover or mix material with
water and shovel into waste container. Wash down spill area
with water containing detergent and flush away with plenty
of water.
Disposal Method: Dispose of virgin (unused)
carbon (waste or spillage) in a facility for non-hazardous
wastes.
Container Disposal: Do not reuse empty
container. Dispose of normal waste removal methods.
SECTION 8 – SPECIAL PROTECTION INFORMATION
TLV or
Suggested Control Value: The current OSHA and ACGIH limit
for dusts which contain more than 1% quartz are as follows
for steam activated coal based carbons:
Respirable
Dust Limit = 0.7 mg/m3 (OSHA & ACGIH) Total Dust Limit =
2.1 mg/m3 (OSHA) Total Dust Limit = 2.0 mg/m3 (ACGIH)
Ventilation: Provide adequate general and local exhaust
ventilation to meet suggested control value requirements.
Respiratory Protection: If needed, use MSHA-NIOSH
approved respirator for dusts, mists and fumes whose TLV is
greater than 0.05 mg/m3.
Eye Protection: Safety
glasses with side shields. Contact lenses should not be worn
when working with activated carbon.
Other Protective
Equipment: Eyewash station in work area.
SECTION 9 -
SPECIAL PRECAUTIONS
Precautions To Be Taken For
Handling And Storing: Activated carbon can be safely stored
in any normal storage area, but away from sources of direct
heat. Any oxygen deficiency may be created when activated
carbon is stored in an enclosed space. Ventilate or wear
self-containtained breathing apparatus.
KEEP OUT OF
REACH OF CHILDREN
ALTHOUGH THE INFORMATION AND
RECOMMENDATIONS SET FORTH IN THIS SHEET ARE BELIEVED TO BE
CORRECT AS OF THE DATE HEREOF, WINSTON COMPANY, INC. MAKES
NO REPRESENTATION AS TO THE COMPLETENESS OR ACCURACY OF SUCH
INFORMATION AND RECOMMENDATIONS. WINSTON COMPANY, INC SHALL
IN NO EVENT BE RESPONSIBLE FOR ANY DAMAGES OF WHATSOEVER
NATURE DIRECTLY OR INDIRECTLY RESULTING FROM THE PUBLICATION
OR USE OF OR RELIANCE UPON SUCH INFORMATION AND
RECOMMENDATIONS.
YOU ARE ENCOURAGED TO ADVISE ANYONE
WORKING WITH OR EXPOSED TO SUCH PRODUCTS OF THE INFORMATION
CONTAINED HEREIN. NO WARRANTY, EITHER EXPRESS OR IMPLIED, OF
MERCHANTABILITY OR FITNESS OR OF ANY OTHER NATURE WITH
RESPECT TO THE PRODUCT OR TO THE INFORMATION AND
RECOMMENDATIONS HEREIN MADE HEREUNDER.
Winston
Company, Inc. ● 7704 East 38th Street ● Tulsa, OK 74145 ●
800-331-9099
|
KEEP OUT OF REACH OF CHILDREN |
ALTHOUGH THE INFORMATION AND RECOMMENDATIONS SET FORTH IN
THIS SHEET ARE BELIEVED TO BE CORRECT AS OF THE DATE HEREOF,
WINSTON COMPANY, INC. MAKES NO REPRESENTATION AS TO THE
COMPLETENESS OR ACCURACY OF SUCH INFORMATION AND
RECOMMENDATIONS. WINSTON COMPANY, INC SHALL IN NO EVENT BE
RESPONSIBLE FOR ANY DAMAGES OF WHATSOEVER NATURE DIRECTLY OR
INDIRECTLY RESULTING FROM THE PUBLICATION OR USE OF OR
RELIANCE UPON SUCH INFORMATION AND RECOMMENDATIONS. YOU ARE
ENCOURAGED TO ADVISE ANYONE WORKING WITH OR EXPOSED TO SUCH
PRODUCTS OF THE INFORMATION CONTAINED HEREIN.
NO
WARRANTY, EITHER EXPRESS OR IMPLIED, OF MERCHANTABILITY OR
FITNESS OR OF ANY OTHER NATURE WITH RESPECT TO THE PRODUCT
OR TO THE INFORMATION AND RECOMMENDATIONS HEREIN MADE
HEREUNDER.
Winston Company, Inc. has lead the
biological water treatment industry for over 25 years now by
offering only the highest quality bacteria and enzyme
solutions for municipal wastewater treatment, sludge
treatment and pond treatment. |
|